詳細(xì)介紹
ITL 900-T
Main characteristics: · Nominal current measurement (IPN): 400 ARMS · Measuring range: +/- 900 A · Excellent linearity: 3 ppm in the operating temperature range · High resolution · Low Initial offset: 20 ppm · Very low offset drift less than 0.3 ppm/K · Overall accuracy @ IPN @ +25°C: < +/- 0.0087 % · Wide frequency bandwidth up to 200 kHz (+/- 3 dB) Features: · DC, AC pulse currents' measurements with galvanic isolation · Fluxgate technology · Electrostatic shield between primary and secondary circuit · Power supply +/- 15 Volt · Operating temperature range from +10 to +50°C · D-Sub 9 male interface output · Current output · Really quick response time (< 500 µs) · Really low output noise Standard compliance: · European Directive EMC 2004 / 108 / EEC: CE Marking · EN 50178 for industrial applications · Typical applications: § Feedback element in high performance gradient amplifiers for MRI § Feedback element in precision current regulated devices (power supplies…) § Precise and high stability inverters § Medical equipment § Energy measurement § Power analyzers § Calibration units Remarks: · Current overload capability · Can be synchronized with an external clock signal · Additional output indicating the transducer state · Additional output indicating when the transducer is synchronized with an external signal · A LED shows normal operation |
Product search results | |||||||||
Model | Primary Nominal Value | Measuring Range | Secondary Signal | Supply Voltage (V) | Accuracy (誤差) | Mounting | |||
ITL 900-T | 400 A | 900 A | 266.667 mA | 15-15 Bi | 0.0087 | Panel |