直銷中國臺灣KOMPASS電磁閥D4-03-2B11A-A15
直銷中國臺灣KOMPASS電磁閥D4-03-2B11A-A15
中國臺灣KOMPASS電磁閥 中國臺灣KOMPASS換向閥
D4-02-3C2-A15 D4-02-3C3-A15 D4-02-3C4-A15
D4-02-3C40-A15 D4-02-3C5-A15 D4-02-3C6-A15
D4-02-3C60-A15 D4-02-3C7-A15 D4-02-3C8-A15
D4-02-3C9-A15 D4-02-3C10-A15 D4-02-3C11-A15
D4-02-3C12-A15 D4-02-2D2-A15 D4-02-2D3-A15
D4-02-2D7-A15 D4-02-2D8-A15 D4-02-2D2A-A15
D4-02-2D3A-A15 D4-02-2D4A-A15 D4-02-2D40A-A15
D4-02-2D5A-A15 D4-02-2D7A-A15 D4-02-2D9A-A15
D4-02-2D10A-A15 D4-02-2D11A-A15 D4-02-2D12A-A15
中國臺灣KOMPASS電磁閥 中國臺灣KOMPASS換向閥
D4-02-3C2-A15 D4-02-3C3-A15 D4-02-3C4-A15
D4-02-3C40-A15 D4-02-3C5-A15 D4-02-3C6-A15
D4-02-3C60-A15 D4-02-3C7-A15 D4-02-3C8-A15
D4-02-3C9-A15 D4-02-3C10-A15 D4-02-3C11-A15
D4-02-3C12-A15 D4-02-2D2-A15 D4-02-2D3-A15
D4-02-2D7-A15 D4-02-2D8-A15 D4-02-2D2A-A15
D4-02-2D3A-A15 D4-02-2D4A-A15 D4-02-2D40A-A15
D4-02-2D5A-A15 D4-02-2D7A-A15 D4-02-2D9A-A15
D4-02-2D10A-A15 D4-02-2D11A-A15 D4-02-2D12A-A15
工作原理
電磁閥里有密閉的腔,在不同位置開有通孔,每個孔連接不同的油管,腔中間是活塞,兩面是兩塊電磁鐵,哪面的磁鐵線圈通電閥體就會被吸引到哪邊,通過控制閥體的移動來開啟或關(guān)閉不同的排油孔,而進油孔是常開的,液壓油就會進入不同的排油管,然后通過油的壓力來推動油缸的活塞,活塞又帶動活塞桿,活塞桿帶動機械裝置。這樣通過控制電磁鐵的電流通斷就控制了機械運動。 [1]
主要分類
1、電磁閥從原理上分為三大類:
直動式電磁閥
原理:通電時,電磁線圈產(chǎn)生電磁力把關(guān)閉件從閥座上提起,閥門打開;斷電時,電磁力消失,彈簧把關(guān)閉件壓在閥座上,閥門關(guān)閉。
特點:在真空、負壓、零壓時能正常工作,但通徑一般不超過25mm。
如果電磁閥本身有問題,又無配件更換的情況下,可采用如下辦法進行應(yīng)急處理:
1、用手撥動電磁閥接頭,直到聽見有“嗒”的一聲時,用手按住接頭,然后用膠布帶纏緊,再把輸入線插頭拔出,作一觸一離試驗,如有“嗒、嗒”的動作聲,則表明已恢復(fù)正常,可繼續(xù)使用。注意上述過程應(yīng)在點火開關(guān)接通狀況進行。
2、如果確認怠速電磁閥損壞,為恢復(fù)怠速的作用。應(yīng)拆下電磁閥,并用合適螺塞堵住,使之不漏氣。這樣,電磁閥就失去了功能,成為沒有怠速電磁閥的化油器。
引起電磁閥不工作的原因可能是導(dǎo)線斷路或接頭松動,電磁閥本身失效。可按以下方法檢修:
1、先檢查點火開關(guān)至電磁閥的導(dǎo)線是否脫落,如果斷路應(yīng)連按緊固,否則,應(yīng)檢查怠速電磁閥。
2、一般電磁閥不工作是因接頭處有松動引起斷電。此時可以把輸入線插頭插好,用手撥弄接頭處。如能聽到“嗒”的一聲,說明此處有松動現(xiàn)象。
3、先接通點火開關(guān),用輸入線接頭和插座一觸一離,聽有無電磁閥動作時發(fā)出的“嗒、嗒”聲。如果有,說明電磁閥良好;如果沒有反應(yīng),可能是電磁閥失效或線路接頭松動,應(yīng)進一步檢查電線接頭。